The AGFA NOVA developing machine is designed for automatic processing of industrial X-ray film. Russian experts have repeatedly stressed the high level of reliability of the NOVA model, while noting the ease of maintenance, low weight and compactness of this machine.
Applications of the developing machine
The AGFA NOVA developing machine has a wide range of functional capabilities for work in the fields of industrial non-destructive testing and is used in stationary and field testing laboratories. The AGFA NOVA machine is widely used by flaw detectors who need to organize work on image processing directly at the inspection site, as well as to speed up the research process and stabilize the image quality.
Examples of poorly dried film without the use of a developing machine
The film clearly shows the uneven distribution of the chemical solution
In addition to the uneven distribution of chemical solution, the image shows dark areas that distort the image.
The above problems and many other disadvantages of manual X-ray imaging are solved by the AGFA NOVA developing machine.
Key features and benefits
An important feature of the AGFA NOVA developing machine is the possibility of rapid development of several x-ray films simultaneously. At the same time, the processing process is fully automated: the transportation of images through the developer, the rinsing bath and the infrared desiccant is carried out without the participation of the operator.
The machine provides the ability to program the desired processing mode. AGFA NOVA independently determines the format of the film and selects the optimal use of chemical reagents. The required parameters (film transit time, temperature, solution distribution) are displayed on the display and maintained without the need for repeated selection of values. Thus, the same quality of the first and subsequent images is achieved.
Another advantage of the NOVA model is its compactness. Low weight and small dimensions make the machine convenient for installation and operation in mobile photo labs.
To facilitate the cleaning and maintenance of the developing machine, the design provides sliding block mechanisms.
The manufacturer General Electric used modern electronics in the car, including local and remote control systems, as well as intelligent power management. The latter significantly reduces the maximum level of energy consumption.
In addition to these advantages, the AGFA NOVA development machine combines the following:
- reduced noise level;
- high performance;
- protection of the film from light and dust;
- computer diagnostics of a technical condition.
The AGFA NOVA machine will ensure uninterrupted radiographic monitoring processes, reduce the workload of personnel and increase the productivity of NK laboratories.
Supply of developing machine
The delivery package includes the AGFA NOVA automatic developing machine, a light-tight casing of the feed tray and a passport. As accessories, it is recommended to purchase two tanks for regenerating solutions, a filter with a cartridge and a working installation table for a developing machine.
Specification:
Comparative specifications of AGFA NDT processors | |||||
Specifications | Name | ||||
NDT-S Eco | NDT-U | NDT-M Eco | NOVA | ||
Processing cycle | Permissible limits, min | 1,5 ÷ 12 | 3 ÷12 | 3 ÷12 | 1,5 ÷ 12 |
Change step, min | 0,5 | 1 | 1 | ||
Standard, min | 8 | 8 | 9 | 8 | |
Productivity (cycle 8 min), films / hour: | |||||
10x48 cm (4 films in a row) | 147 | 106 | 92 | ||
35x43 см | 48 | 34 | 30 | 30 | |
Film | Feed speed, cm / sec | 32 | 23 | 20 | |
Min format, cm | 6x12 | ||||
Width min, cm | 3,5 | ||||
Width max cm | 43 | ||||
Length min, cm | 12 | ||||
Length max, m (width 3.5 cm) | 5 | 2 | no restrictions | ||
Length max, m (width 6 cm) | 5 | ||||
Roll film, Ø, cm | > 9,55 | ||||
Volume, l | Developer tank | 41 | 24 | 10 | |
F1 / F2 fix tank | 40/29 | 20 | 10 | ||
Intermediate tank | 23 | 29 | 9 | 10 | |
Dimensions, m | Length with protruding parts | 1,62 | 1,2 | 1,45 | 1,19 |
Length | 1,11 | 0,73 | 0,86 | 0,94 | |
Width | 0,71 | 0,68 | 0,66 | 0,68 | |
Height | 1,23 | 1,05 | 0,6 | 0,57 | |
Occupied area, m2 |
0,79 | 0,5 | 0,56 | 0,4 | |
Weight (without solutions), kg | 282 | 175 | 117 | 80 |